Voltage
AC: Better than 0.1% of reading (20 to 425V rms, input-to-case). DC (AUX Inputs): +/- 0.2V (24 to
250Vdc, input-to-case)
Current (S10, S13,
Better than 0.1% of reading +/- 500μA (0.5A to 100.0A),
S16 bus 2)
Better than 0.1% of reading +/- 1mA (0.05A to 0.5A).
Current (S11, S14,
Better than 0.1% of reading +/- 100μA (0.5A to 20.0A),
S16 bus 1, S17 bus
Better than 0.1% of reading +/- 250μA (0.05A to 0.5A).
2)
Current (S12, S15,
Better than 0.1% of reading +/- 20μA (0.1A to 4.0A),
S17 bus 1)
Better than 0.1% of reading +/- 50μA (0.01A to 0.1A).
Current (S1C, S2C)
Better than 0.1% of reading +/- 2mA (0.05A to 100.0A, -10C to 70C)
External Split-Core
CTs
Frequency
+/- 0.001 Hertz (accuracy is specified at nominal Frequencies and over operating temperature range)
Phase Angle
+/- 0.2 Deg
Power
Better than 0.2% of reading (>20% of nominal inputs, 1PF to 0.7PF);
Power S1C, S2C
For S1C and S2C split core versions, better than 0.2% of reading +/- 250mVA (>20% of nominal
inputs, 1PF to 0.7PF)
Operating Temperature
-40C to 70C
Relative Humidity
0-95% non-condensing
Installation Category
IC III (Distribution Level) Refer to definitions below.
Pollution Degree
Pollution Degree 2 Refer to definitions below.
Enclosure Protection
IP20 to IEC60529:1989
Altitude
Up to and including 2000m above sea level
Intended Use
Indoor use; Indoor/Outdoor use when mounted in an appropriately rated protective enclosure to
NEMA or IP protection classifications, as required for the installation.