Environmental; Physical; Hot Swap (Hs) Compatibility (P1X Modules); Hardware Configuration - Novatech Bitronics M87X Series Manual

Table of Contents

Advertisement

Indicator LEDs:
Bus Interface:
Power Requirements:
Hot Swap (P1x only):
This product contains fiber optic transmitters that meet Class I Laser Safety requirements
in accordance with the US FDA/CDRH and international IEC-825 standards.

8.4 Environmental

Operating Temperature:
Relative Humidity:
Installation Category:

8.5 Physical

Connections:
Package:

8.6 Hot Swap (HS) Compatibility (P1x Modules)

The blue Hot Swap LED located on the front panel is illuminated to indicate when it is
permissible to extract a board in systems that support the Full Hot Swap System Model.
The M87x currently supports the Basic Hot Swap System Model. The Basic Hot Swap
System Model does not illuminate the blue LED. The blue LED will turn on briefly when a
card is inserted into an energized device or when the device is reset. If the blue LED
remains illuminated after insertion into an M87x or remains illuminated after the S10 Host
module has booted, the associated card is malfunctioning.

8.7 Hardware Configuration

Configuration of the Ethernet interface is not normally required. The M87x is normally able
to detect and adapt to any type of equipment attached to it. Under very rare
circumstances, the user will need to manually configure the link for P1x modules using a
jumper block on the Ethernet interface board. For the vast majority of cases, the factory
default jumper settings (which is equivalent to having no jumpers installed) will provide the
best possible link speed and reliability. The factory default locations for the two jumpers
are 1-2 and 5-6. Section 8.13.1 details other jumper setting suitable for special situations.
ML0021
P1x: Link, 10/100Mb, Collision, Duplex, Transmit, Receive
E1: Activity, Link; E3: Activity, Duplex
Standard 5V CompactPCI
50mA @ 3.3Vdc and 500mA @ 5Vdc (supplied from
backplane)
Complies with Hot Swap specification PICMG 2.1 R1.0 for
Basic Hot Swap (requires Host Processor re-boot).
-40 to 70C
0-95% non-condensing
IC III (Distribution Level), Pollution Degree 2. Refer to definition
on page 9.
RJ45 (copper), ST connectors (62/125um glass fiber)
TM
CompactPCI
Option integrated into H12 host module (E1, E3 options)
August 15, 2018
TM
Backplane
(3U, 4HP) removable module (P1x only)
110
Copyright 2018 Bitronics, LLC