Chargers
Changing the Active Profile (manual)
1: Disconnect the AC power source for a minimum of 20 seconds.
2: Disconnect the charger positive battery lead.
3: Reconnect the AC power source.
4: Touch the positive battery lead to the battery terminal for 3 seconds and then remove.
• The active algorithm will increment to the next stored on the list.
5: Repeat until the desired algorithm is selected.
6: Touch the positive battery lead to the battery terminal for 10 seconds to store the selected algorithm as
active. You should hear a relay in the charger pick up (click).
7: Remove the lead from the battery.
8: Disconnect the AC power source for a minimum of 20 seconds.
9: Reconnect the AC power source and confirm the desired profile is active.
10: Disconnect the AC power source for a minimum of 20 seconds.
11: Reconnect the charger positive battery lead and confirm all connections are secure.
Changing the Active Profile (PC)
The charging profile can be changed using the QuiQ Programmer PC application and a laptop computer with USB
port. Refer to the Special Tools section for part number of the QuiQ Programmer.
This application will also allow viewing the charging history to aid in troubleshooting or uploading other algorithms.
Instructions for using the application are included with the application or contact Delta-Q.
Taylor-Dunn does not offer 3rd party computer application support, contact Delta-Q for assistance in using the
application.
Notes:
Taylor-Dunn does not support charging profiles not already included with chargers purchased from Taylor-
Dunn.
Taylor-Dunn does not provide charging profiles to be uploaded into a charger.