PROGRAMMING

Delta-Q

NOTICE
The algorithms stored in the Delta-Q charger will vary depending on
where the charger was obtained. The following information applies ONLY
to chargers purchased from Taylor-Dunn.
Using the incorrect charging algorithm may result in loss of run time due
to insufficiently charged batteries or premature failure of the batteries
due to overcharging.
The Delta-Q charger has 10 pre-programed algorithms available.
Identify Active Profile
1: Disconnect AC power source and wait for LED's to turn off.
2: Remove the positive charger lead from the battery.
3: Reconnect to AC power source.
4: After the self test completes, the current algorithm code will be displayed on the charger LED's (see
illustration).
Codes 1 through 6 will show on the top LED's and also flash the lower LED.
Codes above 6 will flash the lower LED.
Codes with 2-digits will flash the lower LED in sequence. Each digit will be followed by a short pause. There
will be a long pause after the code is complete and then it will repeat.
The algorithm code will be displayed for 11 seconds.
The following is the list of algorithms available in Taylor-Dunn chargers. Contact Delta-Q for any additional detail or
for information on codes not listed.
Code
Mfg
1
Trojan
7
Trojan
11
Generic
26
Deka
42
Discover
43
Discover
51
Exide/Sonnenschein 180Ah
71
Generic
125
Full River
151
Full River
MB-440-06
Battery
Type
Algorithm
Generic
FLA
T145
FLA
dV/dT
200-255Ah
FLA
dV/dT
8GGC2
GEL
80-150Ah
AGM
Generic
AGM
GEL
140-200Ah
FLA
dV/dT
160-220Ah
AGM
220-290Ah
AGM
Chargers