Mitsubishi Electric CC-Link IE Field NZ2GF12A-60IOLH8 User Manual page 73

Network waterproof remote io-link module
Table of Contents

Advertisement

4.
For each channel, set "Write Value" of "Validation setting".
Item
Device validation setting
Vendor ID
Device ID
Serial number 1-4
Serial number 5-8
Serial number 9-12
Serial number 13-16
*1 When the "Validation setting" is set to "Compatible", enter the vendor ID and device ID of the IO-Link device.
*2 When the "Validation setting" is set to "Identical", enter the vendor ID, device ID, and serial number of the IO-Link device.
Precautions
The following lists the availability of the combinations of the data storage setting and the device validation setting.
: Available, : Not available
Data storage setting
Disabled
Upload
Download
Upload/Download
Clear
*1 When the settings are configured in an unavailable combination, operation of the IO-Link module may become unstable.
When the data storage setting is set to "Upload" or "Download", set the device validation setting to "Compatible" or "Identical".
Device validation setting
Disabled
*1
*1
*1
Setting range
• Disabled
• Compatible
• Identical
*1*2
0000H to FFFFH
*1*2
00000000H to FFFFFFFFH
*2
00000000H to FFFFFFFFH
*2
00000000H to FFFFFFFFH
*2
00000000H to FFFFFFFFH
*2
00000000H to FFFFFFFFH
Compatible
Identical