NRPxxP
Example: Moving termination control
Further settings for this example:
SENSe<Sensor>:TRACe:AVERage:TCONtrol
Every chopper phase is started by a trigger event and lasts the defined trace time. Dur-
ing a chopper phase, the trigger synchronization is high
Every measurement provides a result. After 2 measurements, when the trace average
count is reached, the settled trace data result is available.
1 = Start of the measurement cycle
2 = Trigger events
3 = Noninverted chopper phase
4 = Inverted chopper phase
5 = Trigger synchronization
6 = Averaged trace data result after trace average count is reached
7 = Trace measurement result before average count is reached
8 = Return to the start of the measurement cycle
Example: Average count = 1
SENSe<Sensor>:TRACe:AVERage:COUNt
For average count 1, the setting of the termination control has no impact. In both
cases, the measurement runs for the duration of one trace time. Then, settled trace
data is available, and the power sensor returns to the idle state.
1 = Trigger event
2 = Noninverted chopper phase
3 = Trace measurement result
4 = Trigger synchronization
5 = Return to idle state
User Manual 1179.5760.02 ─ 02
1
2
3
8
1
2
3
5
4
4
7
1
Remote control commands
Controlling the measurement
MOVing
(TRIGger:SYNC:STATe
5
6
ON).