Mitsubishi Electric MELSEC iQ-R Series User Manual page 639

Process cpu module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Event
Event
Event
code
type
category
20100
Operation
Info
20200
20300
20301
20400
20401
20414
20415
20500
20501
20502
20503
20510
24000
24001
24100
24101
24102
24120
24121
24200
24201
24202
24300
Detected event
Description
Error clear
The error was cleared.
Event history clear
The event history was cleared.
SD memory card
The SD memory card was enabled.
enabled
SD memory card
The SD memory card forced disable
forcibly disabled
function was executed and the SD
memory card became ready to be
removed.
Firmware update
RnPCPU firmware update using the
successful via SD
SD memory card was performed and
memory card
completed successfully.
(RnPCPU)
Firmware update
RnPCPU firmware update using the
failed via SD memory
SD memory card was performed and
card (RnPCPU)
was not completed successfully.
Firmware update
Firmware update using the
successful via
engineering tool was performed and
engineering tool
completed successfully.
Firmware update
Firmware update using the
failed via engineering
engineering tool was performed and
tool
was not completed successfully.
CPU module data
Data in the CPU module were
backup succeeded
successfully backed up.
CPU module data
Backup of data in the CPU module
backup failed
failed.
CPU module data
Data were successfully restored to
restoration
the CPU module.
succeeded
CPU module data
Restoration of data to the CPU
restoration failed
module failed.
CPU module data
Backup function cannot be set
backup setting
disabled
Clock setting
The clock data was set.
Remote operation
A remote request (RUN, STOP, or
request accepted
PAUSE) was accepted.
Operating status
The operating status of the CPU
change (RUN)
module was changed to RUN.
Operating status
The operating status of the CPU
change (STOP)
module was changed to STOP.
Operating status
The operating status of the CPU
change (PAUSE)
module was changed to PAUSE.
Starting the program
The program was started.
Stopping the program
The program was stopped.
Creation of new
• A new folder was created.
folders, writes to files/
• A new file was created or data was
*1
folders
written to a file.
*1
File copy
A file was copied.
*1
Folder/file rename
A folder name or file name was
changed.
Module
A module communication test was
communication test
executed.
Detailed information
1
2
Operation
Operation target
source
information
information
Firmware
update
information
(RnPCPU)
Operation
Firmware
source
update
information
information
CPU module
Target folder
data backup/
information of
restoration
the CPU
information
module data
backup/
restoration
function
CPU module
data backup
setting
information
Operation
Clock
source
information
information
(before change)
Remote
operation type
information
Operation
Program start
source
information
information
Program stop
information
Drive/file
information
Copy source
drive/file
information
37 EVENT LIST
37.2 Event List
3
37
Clock
information
(after change)
Copy
destination
drive/file
information
637

Advertisement

Table of Contents
loading