Mitsubishi Electric MELSEC iQ-R Series User Manual page 247

Process cpu module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Registration of device test with execution conditions
This section describes how to register the device test with execution conditions.
■Registration method
Specify each field in the "Register Device Test with Execution Condition" window.
[Debug]  [Device Test with Execution Condition]  [Register]
Window
• When bit device/bit type label is specified
Setting data
Item
Device/Label
Data Type
[Forced ON] button
[Forced OFF] button
Setting Value
[Setting] button
Execution Condition
Program Block
Step No.
Execution Timing
■Registration of multiple device tests with execution conditions to the same step
Multiple device tests with execution conditions can be registered to one step. However, device tests with execution conditions
that have the same device/label name and the same execution timing cannot be registered to one step. When such device
tests with execution conditions are registered, the existing registration is overwritten with new registration.
• Two device tests with execution conditions having different execution timing can be registered to one step
even when they have the same device/label name.
• Different device modification (bit specification of word device, digit specification of bit device, or index
modification) is handled as different device name. Therefore, two device tests with execution conditions
having different device modification can be registered to one step.
• When word device/word type label is specified
Description
Set a device or a label to be registered. ( Page 243 Data that can be set)
Specify a data type. ( Page 243 Data that can be set)
These buttons appears when the data type is set to bit data. Click either button to register the
forced on/off.
This field appears when the data type is set to word data. Enter a setting value in decimal or
hexadecimal format. When setting a hexadecimal value, prefix the numerical value with "H".
(Example: "H16", "H1F") Click the [Setting] button to register the value.
Specify a program block.
Specify a step number for each program. To specify the step number, specify the start step of the
instruction.
Specify whether to change the device/label value before or after the execution of the instruction of
the specified step. ( Page 248 Execution timing)
19 TEST FUNCTION
19.2 Device Test with Execution Conditions