Thermo Scientific 2210AM Manual page 11

Ammonia analyzer
Table of Contents

Advertisement

User Interface
General Description
The user-interface consists of a keypad and a graphical LCD
display. The keypad is located to the right of the display. The
F1 to F4 function keys (soft-keys) take on different meanings
depending on the menu selection. The column on the left of
the soft-keys labels the keys with their appropriate functions.
The RUN key starts the analysis and the STOP key stops the
current functioning of the instrument. The + and - keys allow
for navigation between pages. The ENTER key confirms
selections made in the menus. Additional navigation is
provided by the soft-keys (in appropriate menus), for
left / right or up / down cursor movement.
The graphical LCD display shows the date, analysis label,
time, navigational menus, information and help to the user,
current user, instrument-working mode, current status of the
instrument and the soft-key labels.
The MENU key is used to access the menus.
AMMONIA
Display Fields
1. DATE FIELD shows the current date.
2. CURSOR indicates current selection.
3. APPLICATION NAME FIELD shows instrument name tag.
4. TIME FIELD shows present time.
5. DISPLAY FIELD shows menus / measurements.
6. INFO field shows information / instructions to navigate.
7. USER field shows current user name.
8. MODE field shows whether the instrument is working in
Auto, Manual or Run mode.
9. STATUS field shows current working status of the
instrument.
10. FUNCTIONAL KEYS ASSIGNMENT FIELD shows the
functions allotted to the functional keys.
11. FUNCTION KEYS select functions.
12. OPERATIONAL KEYS are meant for operation of the
instrument.
6 |
Introduction
Symbols used
Escape (Cancel/
Back)
Logged out
(Locked)
Scroll Up
Print
Scroll Left
Accept
Menus Display
A "+" before a menu item denotes that the item has multiple
options.
The Up / Down Arrow keys scroll up or down through options
and ENTER is used to view details of the options.
Pressing the MENU key displays the instrument's Main Menu.
System parameters can be configured from the Main Menu.
The analyzer may be shipped with a
translucent protective cover on the LCD.
NOTE:
Carefully peel off this translucent layer
and discard it.
Measurement Mode Display
In measurement mode, the instrument displays current and
previous readings, units, date and time. The measurement
results can be displayed as large size fonts or normal size
fonts. F1 key will toggle between large and normal fonts.
In AUTO mode, the user can navigate
between different menus even though the
NOTE:
instrument is performing a measurement
or a calibration.
Cursor
Logged in
Scroll Down
Delete
Scroll right
Reject
Orion 2210AM Ammonia Analyzer