USER'S GUIDE
n

XOFF

Mode: All
n
Parameters:
-
XOFF
Use
to select the Stop character to be used to stop input from the computer or terminal.
You can enter the code in either hex or decimal.
The Stop character default value is <CTRL-S> for computer data transfers.
If you're operating in Converse Mode, and there is a chance that activity might fill the PK-232's
buffers, you can define the Stop character as <CTRL-G> ($07), the 'beep' character on many ter-
minals.
n

XON

Mode: All
n
Parameters:
-
XON selects the PK-232 Start character that is sent to the computer or terminal to restart input
from that device.
You can enter the code in either hex or decimal.
The Start character default value is <CTRL-Q> for computer data transfers.
If you're operating in Converse Mode, and there is a chance that activity might fill the PK-232's
buffers, you can define the Stop character as <CTRL-G> ($07), the 'beep' on many terminals.
PK232UG Rev. B 9/86
Mnemonic: XO
0 to $7F (0 to 127 decimal) specifies an ASCII character code
Mnemonic: XON
0 to $7F (0 to 127 decimal) specifies an ASCII character code.
Default: $13 <CTRL-S>
Default: $11 <CTRL-Q>