3
Connect request (SABM or "C") frames and disconnect (DISC or "D") frames are also dis-
played with the headers.
4
Unnumbered acknowledgment (UA) of connect- and disconnect-state frames are also dis-
played with either the characters "UA" or "DM" and a header.
5
Receive Ready (RR), Receive Not Ready (RNR), Reject (RJ), Frame Reject (FRMR) and
(I)-Frames are also displayed.
6
Poll/Final bit, PID and sequence numbers are also displayed.
MDIGI ON|OFF
Mode: Packet
Parameters:
ON -
OFF - Normal monitoring as determined by the monitoring mode commands.

MDIGI

permits you to display packet frames that your monitor would normally not show when an-
other station uses your station as a digipeater. MDIGI helps you to better understand the digipeat-
ing paths that may involve your station, even when you've been unaware of what's happening on
the channel.
MDIGI
Use
to see why your transmitter is being keyed when you're not actively involved in a com-
munication session or when your system is more active than you would expect.
MDIGI
When
is OFF you'll see those frames that include your station as one of the digipeaters, if
your monitor modes have been set this way. If your monitor modes have not been set so you can
see these frames, set MDIGI ON to display them.
n
n
n

MFILTER

1[,
2[,
3[,
Mode: Packet
n
Parameters:
-
MFILTER
Use
to select characters to be "filtered," or excluded from monitored packets. Parameters
n
n
"
1,", "
2", etc., are the ASCII codes for the characters you want to filter. You can enter up to four
characters in either hex or decimal.
To prevent a <CTRL-L> character from clearing your screen, set
To eliminate <CTRL-Z> characters, which some computers interpret as end-of-file markers, set
MFILTER
26.
To eliminate <CTRL-G> characters, which beep your computer or terminal, set
MFROM ALL/NONE, YES/NO call1[,call2..] Mnemonic MF
Mode: Packet
Parameters:
call -
PK232UG Rev. B 9/86
Mnemonic: MD
I and UI frames having your call sign (MYCALL or MYALIAS) as the next digi-
peater in the field are displayed, whether you are connected or discon-
nected.
n
4]]]
Mnemonic: MFI
0 to $80 (0 to 128 decimal) specifies an ASCII character code. Up to four
characters may be specified separated by commas.
ALL/NONE, YES list/NO list
(list of up to eight call signs, separated by commas).
Default: OFF
Default: $07,$13
MFILTER
Default: ALL
6-47
COMMAND SUMMARY
12.
MFILTER
7.
149