Ametek 5100 HD User Manual page 119

Tunable diode laser spectrometer
Hide thumbs Also See for 5100 HD:
Table of Contents

Advertisement

254
r
float
CELLPRES
273
rw
float
CONCMIN
274
rw
float
CONCMAX
344
rwf
float
REFCONC
361
r
float
ALYTE1CONS
362
rw
char[20]
CONCUNITS
363
r
uint
DATAVALID_2
364
r
int16
DMODE_2
369
rw
float
SEALPRESMAX
370
rw
float
SEALPRESMIN
374
r
float
TECTEMP_2
395
rwf
float
TEMPREF_2
430
rw
float
CONCSPAN
431
rw
float
CONCZERO
432
rw
float
CONCSPAN_2
433
rw
float
CONCZERO_2
452
rw
int16
AUTOCAL
453
rw
int16
CALMODE
454
rw
int16
CALDAY
455
rw
int16
CALPERIOD
456
r
uint
CALSTART
457
r
float
ALYTE3CON
458
r
float
ALYTE3CON_UC
459
rw
int16
AUTOADJUST
460
rwf
int16
USESTDDEV
461
r
int16
SYSSTATE_2
462
rwf
float
REFTEMP2
473
rwf
int16
ATEX
474
r
float
SEALPRES
494
rwf
float
REFCONCOMP
495
rwf
float
CELLPRESMAX
496
rwf
float
CELLPRESMIN
497
r
float
ALYTE3MCON
498
rwf
float
CRSOVRCONC
499
r
int16
ALYTESEL
500
rw
int16
CALTIME
501
rw
char[20]
CALSCHEDT
502
r
char[20]
NEXTCAL
344
2
PRESX1 Analog Input Filtered value
379
2
Minimum Concentration
381
2
Maximum Concentration
484
2
Concentration of Reference call
517
2
Analyte 1 Concentration in other unit
519
10
2nd Concentration Unit of Measure for
analyte 1
529
2
Data Valid. 0=Not Valid, 1=Valid
531
1
0=Line-lock mode, 1=Sample, 2=Calib
539
2
Process seal max
541
2
Process seal min
549
2
TEC Temperature Value
585
2
Reference temperature for this diode
651
2
concentration span
653
2
concentration offset
655
2
concentration span 2
657
2
concentration offset 2
687
1
Auto calibration. 0=disabled, 1=enabled.
688
1
0=Zero+Span, 1=Zero, 2=Span
689
1
The last day that the calibration was triggered
by the scheduler
690
1
Cal period in second
691
2
1=perform autocal immediately
693
2
Analyte 3 (merged) concentration
695
2
Unclamped analyte 1 concentration value
697
1
0=do not adjust auto cal; 1=adjust auto cal
698
1
User standard deviation in WIR filter
699
1
System state 2. 100=Not Ready,
201=Measure Run, 502=Idle, 600=diag
700
2
Reference temperature 2
718
1
Boolean, 1=ATEX, 0=normal
719
2
Process seal presure
753
2
Reference compensation
755
2
Cell pressure hi limit
757
2
Cell pressure lo limit
759
2
Analyte 3 (merged) concentration
761
2
Cross-over point for Alyte 3 concentration
763
1
Analyte 3 (merged) concentration
764
1
Time until next cal cycle
765
10
The auto calibration schedule. -1 is disabled.
43
The time should be a number like 14:30:45 for
2:30:45 PM.
775
10
Next schedule for calibration
|
Maintenance
6-19