Table 44: Chassis Alarm Messages for QFX5200-32C-L
Component
Alarm Type
Minor (yellow)
Management
Major (red)
Ethernet
interface
RELATED DOCUMENTATION
Definitions of Safety Warning Levels | 170
Configuring Junos OS to Determine Conditions That Trigger Alarms on Different Interface Types
alarm
(Continued)
CLI Message
FPC 0 Temperature Warm
FPC 0 Temp Sensor Fail
management-
Management interface
interface-name down on node
Recommended Action
Check environmental conditions
and alarms on other devices. Ensure
that environmental factors (such as
hot air blowing around the
equipment) do not affect the
temperature sensor.
Check the system log for the
following error message and report
the message to customer support:
Check whether a cable is connected
to the management Ethernet
interface, or whether the cable is
defective. Replace the cable, if
required.
156