For example, if the activation code is 4D8D6E7A81409365CA1F000028200041FD, enter the following
command:
chvet -o e -k 4D8D6E7A81409365CA1F000028200041FD
b. In an IVM session, validate that the code entry is successful by using the lsvet -t hist
command.
The following is an example of the command output:
time_stamp=03/06/2013 16:25:08,"entry=[VIOSI05000400-0331] CoD advanced
functions activation code entered, resource ID: CA1F, capabilities: 2820."
time_stamp=03/06/2013 16:25:08,entry=[VIOSI05000403-0332] Virtual I/O server
capability enabled.
time_stamp=03/06/2013 16:25:08,entry=[VIOSI05000405-0333] Micro-partitioning
capability enabled.
This ends the procedure.
The procedure does not require you to restart the compute node to activate the PowerVM virtualization
functions.
Note: If you intend to restart the compute node after you complete this procedure, wait at least 5
minutes before you restart the compute node, or before you power off and power on the compute node.
This is to ensure that the activation code is stored in the vital product data on the management card.

Removing the light path diagnostics panel

You can remove this tier 2 CRU, or you can request IBM to remove it, at no additional charge, under the
type of warranty service that is designated for the compute node. Remove the light path diagnostics
panel to replace the panel or to reuse the panel in a new system-board and chassis assembly.
About this task
Figure 29. Removing the light path diagnostics panel
66
Power Systems: IBM Flex System p270 Compute Node Installation and Service Guide