IBM Flex System p270 Compute Node Installation And Service Manual page 161

Table of Contents

Advertisement

B2006006 • B2006015
B2006006
Explanation: During the startup of a partition, a system firmware error occurred when the partition memory was
being initialized; the startup will not continue.
Response: Go to Isolating firmware problems.
B2006008
Explanation: During the IPL of the partition, an error was detected while trying to setup the partition for firmware
use.
The IPL of the partition will not continue.
Response: Contact IBM support.
B2006009
Explanation: An active memory sharing partition is attempting to use a paging space device for which it does not
have ownership.
Response: Verify that the paging space device is not in use by another CEC, and then follow the instructions below
to initialize the paging space device. 1) Power off the partition. 2) Verify that the paging device is not currently in
another CEC's Reserved Pool. 3) Clear the paging space header of the hdisk assigned to the partition. 4) Remove the
paging space from the Reserved Pool. 5) Add the just removed paging space back into the Reserved Pool. 6) Activate
the partition.
B200600A
Explanation: A problem occurred during the startup of a partition. The partition could not reserve the memory
required for IPL.
Response: Contact IBM support.
B2006012
Explanation: During the startup of a partition, the partition LID failed to completely load into the partition main
storage area.
Response: Go to Isolating firmware problems.
B2006015
Explanation: A problem occurred during the startup of a partition. The load source media is corrupted or not valid.
Response: Replace the load source media.
149
Chapter 8. Troubleshooting

Advertisement

Table of Contents
loading

Table of Contents