IBM Flex System p270 Compute Node Installation And Service Manual page 329

Table of Contents

Advertisement

110-XXXX
Explanation: The system halted while diagnostics were executing.
Note: xxxx corresponds to the last three or four digits of the SRN following the dash (-).
1. If your 110 SRN is not listed, substitute the last three or four digits of the SRN for xxxx and go to Failing function
codes to identify the failing feature.
2. Run stand-alone diagnostics and the problem determination procedure for your operating system.
Response:
Failing Item:
v FFC_XXXX
v FFC_221
252B-101
Explanation: Adapter configuration error.
1. Check the BladeCenter management-module event log. If an error was recorded by the system, see POST progress
codes (checkpoints).
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board
Response:
Failing Item:
v FFC_252B
252B-710
Explanation: Permanent adapter failure.
1. Check the BladeCenter management-module event log. If an error was recorded by the system, see POST progress
codes (checkpoints).
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board
Response:
Failing Item:
v FFC_252B
252B-711
Explanation: Adapter failure.
1. Check the BladeCenter management-module event log. If an error was recorded by the system, see POST progress
codes (checkpoints).
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board
Response:
Failing Item:
v FFC_252B
110-XXXX • 252B-711
Chapter 8. Troubleshooting
317