2E16-702 • 2E21-602
2E16-702
Explanation: Error log analysis indicates permanent adapter failure is reported on the other port of this adapter.
Replace the IBM Flex System FC3172 2-port 8Gb FC Adapter. If the problem persists, replace the system board.
Response:
Failing Item:
v FFC_2E16
v FFC_221
2E21-201
Explanation: Adapter configuration error.
1. Check the BladeCenter management-module event log. If an error was recorded by the system, see POST progress
codes (checkpoints).
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board
Response:
Failing Item:
v FFC_2E21
v FFC_221
2E21-601
Explanation: Error Log Analysis indicates adapter failure.
1. Check the BladeCenter management-module event log. If an error was recorded by the system, see POST progress
codes (checkpoints).
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board
Response:
Failing Item:
v FFC_2E21
2E21-602
Explanation: Error Log Analysis indicates an Error Attention condition.
1. Check the BladeCenter management-module event log. If an error was recorded by the system, see POST progress
codes (checkpoints).
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board
Response:
Failing Item:
v FFC_2E21
382
Power Systems: IBM Flex System p270 Compute Node Installation and Service Guide