B2005106 • B2005122
B2005106
Explanation: A problem occurred during the startup of a partition. There is not enough space to contain the
partition main storage dump. The startup will not continue.
Response: Verify that there is sufficient memory available to start the partition as it is configured. If there is already
enough memory, then go to Isolating firmware problems.
B2005109
Explanation: A problem occurred during the startup of a partition. There was a partition main storage dump
problem. The startup will not continue.
Response: Go to Isolating firmware problems.
B2005114
Explanation: A problem occurred during the startup of a partition. There is not enough space to contain the
partition main storage dump. The startup will not continue.
Response: Go to Isolating firmware problems.
B2005115
Explanation: A problem occurred during the startup of a partition. There was an error reading the partition main
storage dump from the partition load source into main storage. The startup will attempt to continue.
Response: If the startup does not continue, look for and resolve other errors.
B2005117
Explanation: A problem occurred during the startup of a partition. A partition main storage dump has occurred but
cannot be written to the load source device because a valid dump already exists.
Response: Use the Main Storage Dump Manager to rename or copy the current main storage dump.
B2005121
Explanation: A problem occurred during the startup of a partition. There was an error writing the partition main
storage dump to the partition load source. The startup will not continue.
Response: Look for related errors in the "Product Activity Log" and fix any problems found. Use virtual control
panel function 34 to retry the current Main Store Dump startup while the partition is still in the failed state.
B2005122
Explanation: Informational system log entry only.
Response: No corrective action is required.