2E37-141 • 2E37-153
2E37-141
Explanation: DMA write test failed. Replace the IBM Flex System EN4054 4-port 10Gb Ethernet Adapter.
Response:
Failing Item:
v FFC_2E37
2E37-142
Explanation: DMA read-write test failed. Replace the IBM Flex System EN4054 4-port 10Gb Ethernet Adapter.
Response:
Failing Item:
v FFC_2E37
2E37-151
Explanation: Internal loopback test failed. Replace the IBM Flex System EN4054 4-port 10Gb Ethernet Adapter.
Response:
Failing Item:
v FFC_2E37
2E37-152
Explanation: Internal loopback IP checksum offload test failed. Replace the IBM Flex System EN4054 4-port 10Gb
Ethernet Adapter.
Response:
Failing Item:
v FFC_2E37
2E37-153
Explanation: Internal loopback TCP checksum offload test failed. Replace the IBM Flex System EN4054 4-port 10Gb
Ethernet Adapter.
Response:
Failing Item:
v FFC_2E37
395
Chapter 8. Troubleshooting
Need help?
Do you have a question about the Flex System p270 Compute Node and is the answer not in the manual?
Questions and answers