IBM Flex System p270 Compute Node Installation And Service Manual page 478

Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 7, "Parts listing for IBM Flex System p270 Compute Node," on page 95 to determine which
components are CRUs and which components are FRUs.
v If an action step is preceded by Trained service technician only, that step must be performed only by a trained
service technician.
Isolation
procedure or
symbolic failing
item
Symptom
FSPSP32
The enclosure has
one of the following
problems:
v The enclosure
VPD cannot be
found.
v The enclosure
serial number is
not programmed.
v The enclosure
feature code is not
programmed.
466
Power Systems: IBM Flex System p270 Compute Node Installation and Service Guide
Action
Record the reason code, which is the last 4 digits of the first word from
the SRC. Perform one of the following procedures based on the value of
the reason code:
v Reason code A46F
1. Perform a firmware update. See "Updating the firmware" on page
16.
2. If the problem persists, replace the system-board and chassis
assembly, as described in "Replacing the system-board and chassis
assembly" on page 83.
v Reason code A460
This procedure must be performed by an authorized service provider
and requires a celogin user ID. If you are not an authorized service
provider, contact your next level of support.
1. Access the Advanced System Management Interface (ASMI). Expand
System Configuration > Program Vital Product Data. Set the
enclosure serial number. This action automatically resets the service
processor.
2. Power on the compute node, as described in "Turning on the
compute node" on page 10.
v Reason code A45F
This procedure must be performed by an authorized service provider
and requires a celogin user ID. If you are not an authorized service
provider, contact your next level of support.
1. Access the Advanced System Management Interface (ASMI). Expand
System Configuration > Program Vital Product Data. Set the
enclosure feature code. This action automatically resets the service
processor.
2. Power on the compute node, as described in "Turning on the
compute node" on page 10.
If you do not see your reason code listed, contact your next level of
support.

Advertisement

Table of Contents
loading

Table of Contents