v By using HMC:
a. In the navigation area, expand Systems Management.
b. Select Servers.
c. In the contents area, select the destination compute node.
d. Click Tasks > select Capacity on Demand (CoD) > PowerVM > View Code Information.
The following is an example of the PowerVM output:
Note: When you request the activation code, you must supply the information that is
emphasized in the following example.
CoD VET Information
System type: 7895
System serial number: 12-34567
Anchor card CCIN: 52EF
Anchor card serial number: 01-231S000
Anchor card unique identifier: 30250812077C3228
Resource ID: CA1F
Activated Resources: 0000
Sequence number: 0040
Entry check: EC
Go to step 3.
v By using FSM:
a. On the Chassis Manager page, under Common Actions, click General Actions > Manage
Power Systems Resources. The Manage Power Systems Resources page is displayed.
b. Select the destination compute node.
c. Click Actions, and select System Configuration > Capacity on Demand (CoD).
d. In the Capacity on Demand window, select Advanced Functions from the Select On Demand
Type list.
e. In the table, select PowerVM as the Type.
f. Click View Code Information.
The following is an example of the PowerVM output:
Note: When you request the activation code, you must supply the information that is
emphasized in the following example.
CoD VET Information
System type: 7895
System serial number: 12-34567
Anchor card CCIN: 52EF
Anchor card serial number: 01-231S000
Anchor card unique identifier: 30250812077C3228
Resource ID: CA1F
Activated Resources: 0000
Sequence number: 0040
Entry check: EC
Go to step 3.
v By using Integrated Virtualization Manager (IVM):
a. Start the IVM, if it is not running already.
b. In an IVM session, enter the lsvet -t code command.
The following is an example of the lsvet command output:
Note: When you request the activation code, you must supply the information that is
emphasized in the following example.
sys_type=7895,sys_serial_num=12-34567,anchor_card_ccin=52EF,
anchor_card_serial_num=01-231S000, anchor_card_unique_id=30250812077C3228,
resource_id=CA1F,activated_resources=0000,sequence_num=0040, entry_check=EC
64
Power Systems: IBM Flex System p270 Compute Node Installation and Service Guide