Agitation Before Resuming A Spray Job - Hardi NAVIGATOR Classic EAGLE 3000 Instruction Book

Hide thumbs Also See for NAVIGATOR Classic EAGLE 3000:
Table of Contents

Advertisement

5 - Operation
8. If the chemical container is empty, it can be rinsed by the "chemical
container cleaning device". Place the container over the multi-hole
nozzle and push the upper lever to the left of the TurboFiller.
DANGER! In order to avoid spray liquid hitting the operator, do
not press the lever unless the multi-hole nozzle is covered by a
container, as spray liquid may otherwise hit the operator!
μ
ATTENTION! The rinsing device uses spray liquid to rinse
containers for concentrated chemicals. Always rinse the chemical
containers with clean water several times, until they are clean before disposal.
9. Flush the TurboFiller with clean water by shifting to suction from the RinseTank or from an external tank. The TurboFiller
suction valve must be open for at least 20 seconds after the rinse water is no longer visible in the hopper, in order to
completely empty the transfer hoses into the MainTank.
μ
ATTENTION! If the suction SmartValve is not shifted to suction from a clean water supply, the hopper rinsing device
uses spray liquid for rinsing the hopper! Cleaning the TurboFiller must always be done, when the spray job is ended,
and together with cleaning the entire sprayer. A cleaning after the last filling, and before spraying, does not ensure a
clean TurboFiller!
10. Close the TurboFiller suction valve, when the hopper has been rinsed. Close the lid.
11. If closed, turn the agitation valve towards "agitation".
12. When the spray liquid is well agitated, turn the handle for pressure
SmartValve towards "spraying" position. The agitation continues
during spraying of the crop.
μ
ATTENTION! If foaming is a problem, turn down the agitation.

Agitation Before Resuming a Spray Job

If interrupting a spray job for a while, severe sedimentation may occur depending on the chemicals used. Before resuming
the spray job, it might be necessary to agitate sediment material.
1. Turn the handle at the suction valve towards "Suction from main
tank".
2. Turn the pressure SmartValve towards "Pressure
draining/TurboFiller".
3. Turn the agitation valve towards "Agitation".
DANGER! It is very important to ensure that the quick coupler lid
is correctly and completely fitted to the filling stud in its locked
position, before turning pressure SmartValve to "Pressure
draining/TurboFiller". Failure to do so may cause risk of
contamination and injury from quick coupler lid being "shot" off
when pressurized! If not possible to fit the lid completely,
lubricate the rubber seal and the grip hooks.
4. Engage the pump and set PTO speed to max. 540 RPM or 1000 RPM (depending on pump model).
5. Agitation has started. Continue agitation for at least 10 minutes.