Tank Level Indicator - Hardi NAVIGATOR Classic EAGLE 3000 Instruction Book

Hide thumbs Also See for NAVIGATOR Classic EAGLE 3000:
Table of Contents

Advertisement

3 - Description
Main Components
A. HC 5500 junction box.
B. Electric junction box for road lights.
C. Electric junction box for boom hydraulics.
D. CleanWaterTank, integrated in the side cover. The CleanWaterTank
is filled at the lid (arrow), when the side cover is closed.
μ
ATTENTION! Only open the right side cover, when the
CleanWaterTank is empty!

Tank Level Indicator

MainTank
The actual liquid level in the MainTank can be observed on the MainTank
level indicator (A), where a plug (B) inside the tube follows the liquid
level, as it is connected to a float inside the tank.
The scale is displayed in litres - multiply by 100 for the reading.
Example: The plug floats at 10 on the scale; this means 1000 litres left in
the tank.
μ
ATTENTION! The level indicator is only a guidance for the liquid
level in the tank.
For the most accurate reading, park the sprayer on level ground
with the sprayer chassis in a horizontal position.
The total deviation of accuracy for the level for each scale mark or
readout value is:
• ± 15% for volumes up to 10% of the nominal tank volume.
• ± 7.5% for volumes between 10 and 20% of the nominal tank
volume.
• ± 5% for volumes above 20% of the nominal tank volume.
RinseTank
The water level in the RinseTank can be observed in the tube (C).
A yellow ball floating inside the tube indicates the water level.
• The ball is at the top of the tube: A full tank.
• The ball is at the bottom of the tube: An empty tank.