Central Station/Pager Communication - GE Concord 4 Installation Manual

Hide thumbs Also See for Concord 4:
Table of Contents

Advertisement

3. If the display continues to show PHONE TEST for 90 seconds or more, enter 1,
system master code and see Troubleshooting.

Central station/pager communication

After doing sensor and phone tests, check that the system is reporting alarms
successfully to the central station or pager.
Caution:
Be sure to contact the central monitoring station before activating outputs
that trigger from an alarm condition.
Account numbers vary when displayed, depending on pager service. Account
numbers are not displayed if Streamlining is turned on.
To test communication with the central station/pager:
1. Call the central station and tell the operator that you will be testing the system.
2. Arm the system.
3. Test each of the touchpad and wireless panic buttons and trip at least one sensor
of each type (fire, intrusion, etc.) to verify correct operation.
4. Check pager displays to verify reports are received. Pagers display an event code,
digit sensor number, and the last four digits of the account number. A pager
display of 999 002 7468 indicates the following:
999 (alarm condition)
002 (sensor/zone in alarm or user number)
7468 (last four digits of account number)
5. When you finish testing the system, call the central monitoring station to verify
they received the alarms.
Table 15 below describes pager system event codes
Table 15: Pager system event codes
Codes
009
111
115
118
119
222
333
Concord 4 Installation Manual
System event
Zone restoral
System disarmed
Sensor test exit
Trouble condition cleared
Alarm canceled
System armed to STAY
System armed to AWAY
Chapter 4: Testing and troubleshooting