GE Concord 4 Installation Manual page 59

Hide thumbs Also See for Concord 4:
Table of Contents

Advertisement

Communication failure
Shortcut: 02003
Default: On
DTMF dialing
Shortcut: 02004
Default: On
Dialer abort delay
Shortcut: 02006
Default: 30 seconds
Cancel message
Shortcut: 02007
Default: On
Pager delay
Shortcut: 02008
Default: 15 seconds
Call wait cancel
Shortcut: 02009
Default: None
Dial tone detect
Shortcut: 02010
Default: On
Concord 4 Installation Manual
This setting determines whether the panel activates trouble beeps to alert
users on the premises that communication to the central station failed.
Failure notification occurs after the third unsuccessful reporting attempt
to the central station/pager.
Failure notification can occur immediately if inadequate phone line
voltage is detected upon the initial dialing attempt.
This setting determines whether the panel uses DTMF tones (on) or pulse
(off) for dialing programmed phone numbers.
This setting determines how much time the user has to abort a panel
alarm report (15 to 45 seconds).
This setting determines whether the panel displays a cancel message
after the user disarms the system to clear an alarm condition.
This setting determines how long a report is delayed to a pager (0 to 30
seconds), after the panel dials the pager number.
The pager delay time should not be set below 5 seconds, unless
necessary.
This feature sets up a dialing prefix to disable the call waiting feature
before the panel makes its first dialing attempt to any programmed
central monitoring station or downloader phone number. The prefix can
be up to eight digits.
Note:
We recommend that you program two pauses in any call wait
cancel dialing prefix to ensure proper operation.
To delete the call wait cancel prefix, with the display showing CALL
WAIT CANCEL (or current setting), press D.
Caution:
Do not change this option from its default until verifying with the
customer that he has call waiting with his phone service provider.
Changing this option from its default without call waiting will prohibit the
panel from calling the central station.
When this setting is on, the panel begins dialing as soon as it detects a
dial tone. When this feature is off, the panel begins dialing a few seconds
after seizing the phone line. There is no dial tone detect on the last dialing
attempt.
Chapter 3: Programming