Chapter 3: Programming
Reporting - partition 1 to 6 settings
Opening reports
Shortcut: 06100 to
06600
Default: Off
Closing reports
Shortcut: 06101 to
06601
Default: Off
No activity option
Shortcut: 06102 to
06601
Default: Off
Duress option
Shortcut: 06103 to
06603
Default: Off
Force armed
Shortcut: 06104 to
06604
Default: Off
62
When this setting is on, the panel sends an opening report to the central
station after disarming the system.
To use this feature, the open/close reports settings under the "Phones
menu" on page 48 must be turned on for the specific CS phone or pager
number.
When this setting is on, the panel sends a closing report to the central
station after arming the system.
To use this feature, the open/close reports settings under the "Phones
menu" on page 48 must be turned on for the specific CS phone or pager
number.
When this setting is on, the panel sends a no activity report to the central
station when the activity timeout expires.
When this setting is on, the system can be controlled using a
programmed duress code (see "Security - partition 1 to 6 setting" on page
47) and will send a duress alarm to the monitoring station.
Do not use a duress code unless it is necessary. Using duress codes often
results in false alarms due to code entry errors. If a duress code is
necessary, use it with the audio verification module to reduce false
alarms and accidental dispatches. The audio verification module is listen
only.
When this setting is on, the panel reports to the central monitoring station
when you "force arm" the system.
Forced arming occurs if you press Bypass when arming the system with
open sensors/zones protesting. Auto-forced arming occurs when you do
not press Bypass when arming the system with open sensors/zones
protesting, and then leave through an entry/exit door and the arming
protest period expires. This causes the system to automatically bypass
the open (protesting) sensors. Auto-forced arming always reports to the
central monitoring station.