5. Contact the central monitoring station when you are finished testing.
Table 17 below describes the system alarm sounds you should hear for each alarm
event.
Table 17: System alarm sounds
Alarm type
Fire
Police/Intrusion
Auxiliary

Light control

Test all lights plugged into X10 lamp modules to verify house code and light number
settings.
To test light control:
1. Press 0, 0 repeatedly to turn all lights on and off together.
2. Press 0, 1 repeatedly to turn light 1 on and off.
3. Repeat step 2 for remaining lights (0 + 2 for light 2, 0 + 3 for light 3, etc.).
4. Arm the system to away. All lights plugged into modules set to unit 1 (or set as
entry lights) should turn on and stay on for 5 minutes. All lights plugged into
modules set to unit 2 should blink three times to indicate the arming level.
Remaining lights should not be affected.
5. Disarm the system. If unit 1 (or entry) lights were on for an entry or alarm, they will
turn off in 5 minutes. Unit 2 lights should blink once to indicate the system is off.
Remaining lights should not be affected.
6. All lights should turn on and remain on during fire and auxiliary/medical alarms.
All lights should flash during a police or intrusion alarm.

Energy saver module (ESM)

Test the energy saver module to verify it overrides the thermostat.
Note:
The system must have high- and low-temperature limits set to test the energy
saver module.
Concord 4 Installation Manual
Alarm sound
Repeating series of three beeps
Continuous tone
Rapid beeps
Chapter 4: Testing and troubleshooting
97