5.13 Restored to Factory Setting (System Reset)

This menu item is used to restore some parameter settings to factory setting
values.
The procedures to set the menu item are as follows.
1. Press the composite keys [Shift]+[P-set] (System) on the front panel to en-
2. Press the Up/Down key or turn the knob to select the System Reset and
3. Press the Left / Right key or turn the knob to adjust the value of this
4. After the parameter settings are complete, press [Enter].
Pin 8 controls the actual output voltage of the instrument from 0V to
500V.
Pin 9 monitors the actual output current of the instrument: When the out-
put current is higher than the upper limit Ilim set by pin 9, the instrument
outputs the current at the value of Ilim.
ter the system menu.
press [Enter].
parameter.
No: Default value, indicates the instrument cancels this menu setting.
Yes: Indicates the instrument restores the factory default settings.
The parameters affected by System Reset and the parameter values after
reset are shown in the following table.
Table 5–3 Initial value of the parameter
Category
Parameter
Voltage setting: Vset
Main
interface
Current setting: Iset
Upper limit of voltage: Vlim
Upper limit of current: Ilim
Copyright © Itech Electronic Co., Ltd.
Basic Operation
Initial Value
One percent of the rated
voltage of the
instrument
One percent of the rated
current of the instrument
Upper limit value: One
percent of the rated volt-
age of the instrument
One percent of the rated
current of the instrument