Protect menu. In addition, the power supply also provides over temperature pro-
tection and Sense reverse connection protection.
The descriptions of Protect menu are listed in the table below.
Protection function menu for the power supply
Protect
OVP
OCP
OPP
UCP
Copyright © Itech Electronic Co., Ltd.
Overvoltage protection
Turn the OVP function off. (Def)
Off
On
Turn the OVP function on.
Level
Delay
Overcurrent protection
Turn the OCP function off. (Def)
Off
On
Turn the OCP function on.
Level
Delay
Overpower protection
Turn the OPP function off. (Def)
Off
On
Turn the OPP function on.
Level
Delay
Undercurrent protection
Turn the UCP function off. (Def)
Off
On
Turn the UCP function on.
Warm-up
Power Supply Function
OVP limit
Protection delay time,
see
Protection
Delay.
OCP limit
Protection delay time,
see
Protection
Delay.
OPP limit
Protection delay time,
see
Protection
Delay.
Indicates the instrument
warm-up time. This time
is set to prevent the in-
strument from triggering
protection when the cur-
rent is rising. Because
this transient condition
should not be
58
Need help?
Do you have a question about the IT6000D Series and is the answer not in the manual?
Questions and answers