1. Press the composite keys [Shift]+[I-set] (Function) on the front panel to en-
2. Select 1. LIST: Off and press [Enter].
3. Press the Left/Right key to select Open and press [Enter].
4. Press the Left/Right key to select Internal and press [Enter].
5. Set the name of the List file to be recalled (that is, the file name set in Edit),
6. Press the Left/Right key to select Run and press [Enter].
7. Turn on the [On/Off].
8. Based on the selected trigger method, perform the trigger operation.
Stop Running the List Program
When the List program is running, if you need to stop running, you can do the
following: Press the composite keys [Shift]+[I-set] (Function) on the front panel
to enter the function menu.
At this point, the interface will prompt whether to stop the running of the Func-
tion, you can press the Left/Right key to select Stop, then the running will be
stopped, and the Function menu item will be displayed, you can re-enter the
Function menu for editing; if Reset is selected, it means to stop the present run-
ning and return to the main interface to wait for the next trigger operation; if
Pause is selected, it means that the present running is suspended, and you can
continue to run by selecting Resume.
ter the function menu.
and press [Enter].
The interface returns to the main interface of the LIST function, which is dis-
played as follows:
FUNCTION
LIST
Run Edit Open Export
At this point, the interface returns to the main interface of the system and
LIST RUN is displayed in the lower right corner.
Take the manual trigger as an example. Press [Shift]+[On/Off](Trigger) on
the front panel to run the selected List file. For details about the List trigger
method, see
5.8 Select Trigger Source (Trig
The system will adjust the working mode of the power supply according to
the CC or CV priority mode set in the List file. For example, if the current
power supply is in the CV priority mode, and the list file to be run is set to the
CC priority mode, then the power supply will work in the CC priority mode
after the List file is triggered to run.
After the List file finishes running, the system determines whether to return
to the working mode before the List is run according to the Normal or Last
option you selected.
Copyright © Itech Electronic Co., Ltd.
Power Supply Function
Source).
71