• The lap must be longer than 20 seconds.
• The lap must be greater than 100 m.
• The maximum speed achieved must be greater than 40 km/h.
• The lap is over half the distance of the stored reference lap.
• The lap time does not exceed 43'40.00".
You can also choose to ignore short laps from being used to create the reference lap by entering a Minimum Lap
Time in the Settings.
When Performance Box Touch is creating a reference lap, a 'Creating a Reference Lap' message will be displayed on
the Main Lap Timing Screen in the Delta-T section and the reference lap section will show a rolling lap time. The LEDs
will also illuminate
blue
during the creation process.
Unless you fix the Reference Lap, Performance Box Touch will update the reference lap if you have a faster lap or if
the new lap distance is more than double of the stored reference lap.
You can also load reference laps from previously saved or provided files and you can save your reference lap for
future use.
The reference lap will be retained after each power cycle.
Lap Timing Settings
You can access the Lap Timing settings screen by selecting the
settings are covered on 2 pages and this is where you choose the lap timing parameters.
You can access the different pages by selecting the Forward and Back arrows at the bottom right of the screen or
by swiping left or right.
https://en.racelogic.support//Product_Info/Performance_Meters/Performance_Box_Touch/Performance_Box_Touch_V2/
Quick_Start_Guide_%E2%80%93_Performance_Box_Touch_V2/Quick_Start_Guide%3A_Lap_Timing_Mode_-
Settings button
at the bottom left of the screen. The
_Performance_Box_Touch_V2
18

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pbt-v2Rlpbt-v2

Table of Contents