The screen is split into 2 halves:
• Left-hand side:
◦ Lap time: This will show either a live rolling lap time or a static previous lap time, depending on the Rolling
Lap Time settings. If you choose to display a rolling lap time, the time for the just-finished lap will be displayed
for 5 seconds at the start of a new lap, before it reverts to display the current live lap time again. If it has not
crossed the start/finish line yet, it will display the circuit name/layout with a distance countdown to the start/
finish line (if it has a satellite lock). If you have enabled Standing Start, the message 'Standing Start Mode
Enabled' will be displayed. If you have not detected/defined a start/finish line, a 'No start line' warning will be
displayed.
◦ Time difference to best lap: This is the time difference between the last completed lap time and the quickest
lap time. It is displayed if you set it up in the Rolling Lap Time settings. It will either display continuously, if you
have chosen a static lap time, or it will appear for 5 seconds after a lap has been completed if you have chosen
the rolling lap time. If the start/finish line has yet to be crossed or a lap hasn't been completed, it will not be
shown.
◦ Reference lap time: Displays the current active reference lap time and will update when the reference lap is
superseded by a faster lap time unless the Reference Lap is fixed in the Settings. If you have fixed a
reference lap, a padlock icon will appear to the right of the reference lap's heading. If a reference lap is being
created, the rolling lap time will show.
• Right-hand side:
◦ Delta-T: Presents a live difference in lap time between the current lap time and the stored and active reference
lap at the current location on the track. If the detected speed drops below 10 km/h or the satellite reception is
lost (less than 4 satellites), the time comparison will freeze on the last known valid value until the speed is
increased or the satellite reception is regained. If you are creating a reference lap, a 'Creating a Reference
Lap' message is displayed.
▪ If the current lap is faster than the reference lap, the value will be signed negative and
▪ If the current lap is slower than the reference lap, the value will be signed positive and
▪ If the current lap is the same as the reference lap, the value will be unsigned and black in colour.
◦ Session time: Total time passed within the session.
◦ Completed lap count: Number of completed laps within the session.
Delta-V:
When there is a stored and active reference lap, the 4 LEDs at the top of the screen will provide a live reference lap
speed comparison at the current location on track in relation to the Delta-V Range settings.
• If the current lap is faster than the reference lap, the LEDs will be
• If the current lap is slower than the reference lap, the LEDs will be
• If the current lap is the same speed as the reference lap, the LEDs will be off.
The main lap timing screen can be reset by pressing the
https://en.racelogic.support//Product_Info/Performance_Meters/Performance_Box_Touch/Performance_Box_Touch_V2/
Quick_Start_Guide_%E2%80%93_Performance_Box_Touch_V2/Quick_Start_Guide%3A_Lap_Timing_Mode_-
green
in colour.
red
in colour.
Reset
button at the bottom of the screen or by pressing and
green
in colour.
red
in colour.