Additional text in the adjustment software when a patient weight ≤ 150 kg is entered in the adjustment
software "Please note that the set patient weight exceeds the product specification!"
A maximum body weight of 150 kg including additional weight is permissible with the current knee joint. Ensure
this weight is not exceeded.
Updating the X-Soft adjustment software
1) Click "Help > About" in the menu bar of the Data Station when you are connected to the Internet.
→ The window opens with the versions of the previously installed programs and the manufacturer's address.
2) Click the "Check for updates" button in this window.
→ A search for updates of previously installed software products and components is performed via the Inter­
net.
3) If updates are available, click "Download" in the column on the right in order to download and save the
update.
4) Extract the "ZIP file" and execute it.

7.1.1.2 Data transfer between the product and the PC

Product settings using the adjustment software can only be made via Bluetooth data transfer. For this purpose, a
Bluetooth wireless connection must be established between the product and the PC using the "60X5 BionicLink
PC" Bluetooth adapter. The installation and use of the "60X5 BionicLink PC" adapter are described in the instruc­
tions for use supplied with the adapter.

7.1.1.3 Preparing the product to connect to the adjustment software

If the product does not emit any signals when querying the charge level (see page 79), the battery is drained or the
product is switched off.
Switching on the product
1) Connect the power supply with battery charger to the wall socket.
2) Connect the battery charger to the product.
3) Wait for feedback signals.
4) Disconnect the battery charger from the product.
→ After feedback signals are emitted (self test), the product is switched on.
Switching on Bluetooth
Upon delivery the Bluetooth function of the prosthesis is switched on.
The Bluetooth function can be switched off using the Cockpit app or the adjustment software. When the Bluetooth
function is switched off, it is only turned on temporarily for 2 minutes after connecting/disconnecting the battery
charger and is then turned off again automatically. When a connection with the PC is active (the
lit up), the Bluetooth function is not switched off automatically.

7.1.2 Removing the Protective Cover

1) Open the closures.
2) Spread open the Protective Cover and remove it from the knee joint.
3) Fasten the two closures after removing the Protective Cover.

7.1.3 Shortening the Tube Adapter

CAUTION
Incorrect processing of tube
Falling due to damage to the tube.
► Do not clamp the tube into a vice.
► For shortening the tube, use only a tube cutter.
CAUTION
Damage to the cable while shortening the tube adapter
Falling due to unexpected product behaviour as the result of switching into safety mode.
► When shortening the tube adapter, make sure the cable does not get damaged.
1) Determine the required length of the tube adapter using the configuration assistant in the adjustment software.
Genium X3 3B5-3/3B5-3=ST
Preparing the product for use
symbol is