Guidance and manufacturer's declaration – Electromagnetic emissions
Emission test
RF Emissions
CISPR 11
Harmonic Emissions
CEI 61000-3-2
Harmonic Emissions
Voltage fluctuations/flicker
emission
CEI 61000-3-3
Guidance and manufacturer's declaration – Electromagnetic Immunity
The device is intended for use in the electromagnetic environment specified below. The customer or the user of the
device should assure that it is used in such an environment.
Immunity Test
Electrostatic discharge
IEC 61000-4-2
Fast transient/burst
IEC 61000-4-4
Sovratensioni (surge)
IEC 61000-4-5
Voltage dips, short
interruptions and
voltage variations on
power supply input
lines
EC 61000-4-11
Easytech s.r.l. – Genu Iso/Plus User's Manual
Safety related to Emission (EN 60601-1-2)
Conformity
Group 1
Class A
Class A
Compliant
Safety related to Immunity (EN 60601-1-2)
Conformity
Test Level
± 2,4,8 kV contact
Compliant
± 2,4,8,15 kV air
±2 kV, 100 kHz for
Compliant
power supply
lines
±1KV differential
Compliant
mode
±2KV common
mode
100% drop, 0/5
Compliant
periods, 0°, 45°,
90°, 135°, 180°,
225°, 270°, 315°
100% dip, 1 period
30% dip, 25/30
periods
Electromagnetic Environment - Guidance
The appliance use RF energy only for its internal
function. Therefore, its RF emissions are very low
and are not likely to cause any interference in
nearby electronic equipment.
The
appliance
is
establishments other than domestic, and may be
used in domestic establishments and those
directly connected to the public low-voltage
power supply network that supplies buildings
used for domestic purposes
It
is
possible
to
establishments,
establishments and those directly connected to
the public low-voltage power supply network
that
supplies
buildings
purposes.
Electromagnetic Environment -
Guidance
Floors should be wood, concrete or ceramic
tile. If floors are covered with synthetic
material, the relative humidity should be at
least 30 %.
Mains power quality should be that of a
typical commercial or hospital environment.
Mains power quality should be that of a
typical commercial or hospital environment.
Mains power quality should be that of a
typical commercial or hospital environment.
If the user of the device requires continued
operation during power mains interruptions,
it is recommended that the device be
powered from an uninterruptible power
supply or a battery.
rev. C
suitable
for
use
in
use
the
device
in
including
domestic
used
for
domestic
Pag. 10 di 97
all
all

Advertisement

Table of Contents
loading

Related Products for easytech Isokinetic Genu Iso

This manual is also suitable for:

Isokinetic genu plus

Table of Contents