Environmental Specifications - Xantrex TC1012 Owner's Manual

Truecharge2 series
Hide thumbs Also See for TC1012:
Table of Contents

Advertisement

Absorption voltage:
±0.1 V for 12 Vdc units
±0.2 V for 24 Vdc units
Float voltage:
±0.1 V for 12 Vdc units
±0.2 V for 24 Vdc units
Equalize mode current
Equalize mode—maximum
output voltage
Off-state current draw
(without remote installed)
Voltage regulation

Environmental Specifications

Operating range (full performance) 0 – 50 °C (32 – 122 °F)
Current de-rating (above 50 °C
ambient temperature)
Storage
Humidity
975-0401-01-01
25 °C (77 °F)
Flooded
GEL
AGM
Lead-calcium
25 °C (77 °F)
Flooded
GEL
AGM
Lead-calcium
50% rated output ±6%
12 V units: 16 ±0.1 Vdc
24 V units: 32 ±0.2 Vdc
12 V units: <35 mA dc
24 V units: <20 mA dc
Uncompensated load voltage regulation
< 0.1Vdc drop from 0 Amps to rated current
output at charger output terminals (adds in
series with recommended 3% limit for user's
battery cable voltage drop).
up to 80% derating Imax
50 – 65 °C (122 – 149 °F)
–40 to 80 °C (–40 to 176 °F)
5 – 95%, RH non-condensing
Environmental Specifications
12 Vdc units
14.4
14.2
14.3
15.5
12 Vdc units
13.5
13.8
13.4
13.5
24 Vdc units
25 °C (77 °F)
28.8
28.4
28.6
31.0
24 Vdc units
25 °C (77 °F)
27.0
27.6
26.8
27.0