Environmental Specifications - Xantrex TRUECHARGE 2 Installation Manual

Hide thumbs Also See for TRUECHARGE 2:
Table of Contents

Advertisement

Absorption voltage:
±0.1 V for 12 Vdc units
±0.2 V for 24 Vdc units
Float voltage:
±0.1 V for 12 Vdc units
±0.2 V for 24 Vdc units
Equalize mode current
Equalize mode—maximum
output voltage
Off-state current draw
(without remote installed)
Voltage regulation

Environmental Specifications

Operating range (full performance) 0 – 50 °C (32 – 122 °F)
Current de-rating (above 50 °C
ambient temperature)
Storage
Humidity
975-0402-01-01
This guide for use by qualified installers only
Elcodis.com
electronic components distributor
Environmental Specifications
12 Vdc units
25 °C (77 °F)
Flooded
14.4
GEL
14.2
AGM
14.3
Lead-calcium
15.5
12 Vdc units
25 °C (77 °F)
Flooded
13.5
GEL
13.8
AGM
13.4
Lead-calcium
13.5
50% rated output ±6%
12 V units: 16 ±0.1 Vdc
24 V units: 32 ±0.2 Vdc
12 V units: <35 mA dc
24 V units: <20 mA dc
Uncompensated load voltage regulation
< 0.1Vdc drop from 0 Amps to rated current
output at charger output terminals (adds in
series with recommended 3% limit for user's
battery cable voltage drop).
up to 80% derating Imax
50 – 65 °C (122 – 149 °F)
–40 to 80 °C (–40 to 176 °F)
5 – 95%, RH non-condensing
24 Vdc units
25 °C (77 °F)
28.8
28.4
28.6
31.0
24 Vdc units
25 °C (77 °F)
27.0
27.6
26.8
27.0
A–5

Advertisement

Table of Contents
loading