Scope Of Delivery And Accessories; Scope Of Delivery; Accessories - Otto Bock Genium X3 Instructions For Use Manual

Bionic prosthetic system
Hide thumbs Also See for Genium X3:
Table of Contents

Advertisement

CAUTION
Independently applied changes or modifications made to the mobile device
Falling due to altered damping behaviour as a result of unexpected switching to a MyMode.
► Do not make any independent changes to the hardware of the mobile device on which the app is installed.
► Do not make any independent changes to the software/firmware of the mobile device that are not included in
the update function of the software/firmware.
CAUTION
Improper mode switching with the mobile device
Falling due to unexpected product behaviour because of changed damping behaviour.
► Ensure that the patient stands securely during all switching processes.
► Inform the patient that the changed damping characteristics have to be verified after switching, and feedback
from the acoustic signal emitter and the mobile device display must be observed.
► Switching back to basic mode is mandatory once the activities in the MyMode have been completed.
NOTICE
Destruction of the mobile device due to falling or penetration of water
Malfunction of the mobile device.
► Note the instructions for use for the mobile device.
► If it should no longer be possible to switch back from a MyMode to basic mode, the component can only be
switched back to basic mode by using a movement pattern (see page 47) or by connecting/disconnecting the
inductive battery charger.
NOTICE
Failure to observe the system requirements for the installation of the Cockpit app
Mobile device malfunction.
► The Cockpit App should only be installed on mobile devices and versions which comply with the specifica­
tions in the respective online stores (e.g. Apple App Store, Google Play Store, ...)
INFORMATION
The illustrations in these instructions for use are only examples and may deviate from the respective mobile device
being used and the version.

5 Scope of Delivery and Accessories

5.1 Scope of delivery

1 pc. 3B5-X3=ST Genium X3 - Bionic Prosthetic
System (with threaded connector) or
1 pc. 3B5-X3 Genium X3 - Bionic Prosthetic System
(with pyramid connector) or
1 pc. 3B5-2=ST Genium X3 (with threaded con­
nector) or
1 pc. 3B5-2 Genium X3 (with pyramid connector)
1 pc. 2R19 AXON tube adapter
Cockpit app for download from the website: https://www.ottobock.com/cockpitapp
"Cockpit 4X441-ANDR=V*" app for Android
Only when "DUAL" marking is present (Important information)
"Cockpit 4X441-IOS=V*" app for iOS

5.2 Accessories

The following components are not included in the scope of delivery and may be ordered separately:
Genium X3 Protective Cover: 4X900
Genium X3 - Bionic Prosthetic System 3B5-X3/3B5-X3=ST,Ge­
nium X3 3B5-2/3B5-2=ST
Scope of Delivery and Accessories
1 pc. 757L16* power supply
1 pc. 4E60* inductive charger
1 pc. cosmetic case for battery charger and power
supply
1 pc. 646C107 Bluetooth PIN card
1 pc. 647F542 prosthesis passport
1 pc. Instructions for use (qualified personnel)
1 pc. Instructions for use (user)
Genium X3 Protective Cover: 4X193-1