Scope Of Delivery And Accessories; Scope Of Delivery - Otto Bock AxonArm Ergo 12K501 Series Instructions For Use Manual

Hide thumbs Also See for AxonArm Ergo 12K501 Series:
Table of Contents

Advertisement

Scope of Delivery and Accessories

CAUTION
Independent manipulation of Axon-Bus components
Injury due to faulty control or malfunction of the Axon-Bus prosthetic system.
► Manipulations to the Axon-Bus prosthetic system other than the tasks described in these instructions for use
are not permitted.
► Do not damage the battery or separate the connection cables between the battery packs.
► The Axon-Bus prosthetic system and any damaged Axon-Bus components may only be opened and/or
repaired by certified Ottobock Myo-Service technicians.
CAUTION
Incorrect electrode settings
Injury due to faulty control or malfunction of the product.
► The electrodes are to be placed on intact skin only and with as much electrode-skin contact as possible. In
the case of strong interference from electronic devices, the position of the electrodes should be checked and
changed if necessary. If the interference cannot be eliminated or if you do not achieve the expected results by
adjustment or selection of the appropriate control programme, please contact Ottobock Myo-Service.
► Set the electrode gains as low as possible to reduce the risk of malfunctioning due to strong electromagnetic
radiation (e.g. visible or concealed theft prevention systems at the entrance/exit of stores, metal detect­
ors/body scanners for persons (e.g. in airports) or other sources of strong electromagnetic interference (e.g.
high-voltage lines, transmitters, transformer stations, computer tomographs, magnetic resonance tomo­
graphs, etc.).
► Allow the patient to rest during the adjustment of the electrodes; otherwise, muscle fatigue will lead to incon­
sistent results. As a result, the therapist will tend to set the electrode gains too high.
CAUTION
Risk of pinching in elbow joint flexion region
► Injuries due to pinching of body parts.
→ Ensure that fingers and other body parts are not in this area when bending the elbow joint.
CAUTION
Manual unlocking of elbow lock under load
Injury by release of elbow lock under load.
► Particular caution should be exercised when unlocking the elbow lock while lifting heavy loads.
► Be careful when unlocking the lock under such conditions due to the possibility of injury.
CAUTION
Penetration of dirt and moisture
Injury due to faulty control or malfunction of the Axon-Bus prosthetic system.
► Do not let foreign particles or liquids get into the prosthetic arm.
► Do not expose the prosthetic arm, especially the elbow joint, to dripping or splashing water.
► Wear the prosthetic arm and especially the elbow joint under suitably resistant clothing in the rain.
NOTICE
Coating, gluing or painting the product
Damage or fracture due to chemical processes.
► The product must not be coated, glued or painted.
5 Scope of Delivery and Accessories

5.1 Scope of delivery

1 pc. 12K501 AxonArm Ergo
1 pc. Lamination protection cover (disc with arrow)
1 pc. Lamination protection cover (hollow ball)
1 pc. Cable lock
8
AxonArm Ergo 12K501=*

Advertisement

Table of Contents
loading

Table of Contents