Configuring with Remote Display

Read "Configuring with DIP Switches" on page 1–9 and use Figure 1-6 to locate
the DIP switches. Ensure DIP switch # 8 is UP as this is the setting for optional
remote display installed.
There will be a short delay of about 15 seconds before the remote display begins
reporting. The remote display will use this time to query the charger for the current
operating conditions.
If AC was already applied, ensure that the charger is on by pressing
necessary.
To configure the battery bank type:
1. Press and hold
2. Press
The BC Series will default to Bank 1 and will show the present battery type
setting.
3. Press
indicator light will illuminate to show which bank has been selected.
4. Press
selected a battery type that is different from the present configuration, the bank
indicator light flashes.
Set the
If your battery is
Flooded Lead Acid
(has removable caps intended for refilling)
GEL
(any sealed type except AGM)
Absorbed Glass Mat (AGM)
Lead Calcium
Custom
(if pre-configured at factory)
5. Press and hold
type. If n o is displayed, verify that you are setting the correct battery type and
try again.
975-0188-01-01
until s e t (setup) is displayed.
MODE
to select the battery type configuration programming mode.
TYPE
repeatedly to select which bank you are setting up. The bank
BANK
repeatedly to select the battery type for each bank. When you have
TYPE
according to the table below:
TYPE
/
ON
STANDBY
until y e s is displayed to store the selected battery
Configuring the BC Series
/
ON
STANDBY
then select
F L a
G E L
A G M
L d C
C U S
if
1–11