Things to be aware of
When the BC Series is operating, fans and lights (DC loads) may vary in speed or
intensity. This is normal. The BC Series will not harm any load connected to it as
long as there is a battery present on that bank.
When you initially turn the BC Series on and configure it, it is possible that some
banks may be disqualified. Because the charger is able to detect unhealthy batteries
and disqualify them, batteries that may have appeared healthy before will now be
correctly identified as needing attention.
Perform these disqualification checks in the order shown:
1. Wait 15 minutes for the next battery detection cycle. The warning may be
temporary.
2. Verify that the battery meets the minimum AmpHour rating (BC1524: 30 Ah,
BC2524: 50 Ah, BC3012: 60 Ah, BC5012: 100 Ah)
3. Try adding a small DC load.
4. Replace the battery.