Table 2-1 Reading BC Series Status
Charger Status
Charging in bulk or absorption mode.
Remote display shows scrolling display of charging
state, battery voltage in volts and charging current in
amps.
Indicator lights indicate the charging current in % of
full charge. At transition points when the current is
changing, two indicator lights may flash alternately,
then settle into the new charging current reading.
Equalizing.
Charging indicator light flashes once every four
seconds if bank 1 is being equalized, twice every four
seconds if bank 2 is being equalized, and three times
every four seconds if bank 3 is being equalized.
Float mode of three stage charging or rest mode of
two stage charging.
All batteries have been fully charged.
A battery has been disqualified while in float mode of
three stage charging or rest mode of two stage
charging.
A battery has been disqualified while in bulk or
absorption mode.
Non-charger fault condition.
Any fault condition that prevents the charger from
charging one or more banks, but is not a charger
failure. Remote display shows details of fault.
975-0188-01-01
Accessing Charger Information
Onboard Status Indicator Lights
Charging indicator light illuminates
Charging indicator light flashes
Ready indicator light illuminates
25% current indicator light flashes
25% current indicator light flashes
Fault indicator light illuminates
Remote
Display
or
B U L
A B S
E Q U
or
F L o
R d y
or
F L o
r d y
d i s
E R R
B A T
P o L
(example)
2–13