Transitioning the BC Series to On, Disabled or Off

There are two ways to turn the BC Series on:
connect AC power at the source
press
There are two ways to disable the BC Series:
WARNING: Shock hazard
The BC Series still has live voltage while disabled. Even when AC power is removed, if the
BC Series is connected to a battery on bank 1, the unit will take power from the battery. The
only time the BC Series is de-energized completely is when both AC and DC are
disconnected.
disconnect AC power at the source
press
The BC Series continues to monitor the batteries, but will not charge them.
There is only one way to safely turn the BC Series off:
disconnect the AC power at the source and disconnect all DC batteries.
This is the only state where the BC Series is completely discharged.
When the BC Series is disabled or off, the optional remote display is inactive.
975-0188-01-01
/
on the optional remote display if AC is still connected.
ON
STANDBY
/
on the optional remote display.
ON
STANDBY
Transitioning the BC Series to On, Disabled or Off