Temperature Specifications; Protection Features - Xantrex BC3012 User Manual

Table of Contents

Advertisement

Specifications

Temperature Specifications

Nominal ambient
Operating range
Current de-rating
Storage
Humidity

Protection Features

Battery reverse polarity
Safe non-operating battery voltage 35 VDC maximum
Over-voltage limits
Output current limit
Over-temperature
Current derating in ambient
temperatures
Battery over-temperature
protection
A–4
25 °C (77 °F)
0 – 50 °C (32 – 122 °F)
approx. 2% (Imax) / °C (50 – 65 °C) (122 – 149 °F)
-40 – 80 °C (-40 – 176 °F)
5 – 95%, RH non-condensing
No damage incurred by reverse polarity.
The BC Series will stop charging any bank that has a
voltage greater than + 0.5 V over the temperature
compensated absorption voltage. It will restart when
this voltage is + 0.2 V.
BC3012:
30 – 33 ADC
BC5012:
50 – 55 ADC
BC1524:
15 – 16.5 ADC
BC2524:
25 – 27.5 ADC
Internal charger temperature is measured. Unit shuts
down and restarts as follows:
Over-temperature shutdown at 75 °C (167 °F)
Over-temperature restart at 70 °C (158 °F)
Rated current to 50 °C (122 °F)
2%/ °C derating above 50 °C (122 °F)
Battery temperature, as sensed by the battery
temperature sensor (if installed), results in the
charger no longer charging the individual battery or
bank at a battery temperature of 55 °C (131 °F).
975-0188-01-01