10 Input Assemblies (Drive Produces)
Parameter
Torque Reference
PG Count Value
Frequency Command
Output Frequency
Output Current
INV Terminal A1 Input
Main DC Voltage
Error Code
F7-33 Alarm Code
F7-34 Output Power
F7-35 Terminal A2 Input
F7-36 INV Terminal 1-12
F7-37 Terminal A3 Input
F7-38 PG Count Value (CH 2)
F7-39 NetRef (Status)
F7-40 Drive Software Version
44
Not Supported on V1000
Contained MEMOBUS/Modbus Address
Monitor parameter U1-01
Actual Drive Speed
Monitors drive output frequency.
Unit depends on o1-03.
Unit is not affected by Speed Scale SS.
Actual Output Current
Monitors drive output current.
Unit is 0.01 A
Unit is not affected by Current Scale CS.
MEMOBUS/Modbus (0x46)
Monitor parameter U1-13
Main Circuit DC Voltage
Monitor parameter U1-07
U2-01 converted using fault code table
Programmable: MEMOBUS/Modbus (0x7F)
Programmable: MEMOBUS/Modbus (0x47)
Monitor parameter U1-08
Programmable: MEMOBUS/Modbus (0x4F)
Monitor parameter U1-14
Programmable: Only 1 - 7 available on V1000, MEMOBUS/Modbus (0x49)
Monitor parameter U1-10
Programmable: MEMOBUS/Modbus (0x50)
Monitor parameter U1-15, not supported on V1000
Programmable: MEMOBUS/Modbus (0xF1)
Serial interface Control Response
Status of reference command from Network
0: Reference command is not from network
1: Reference command is from network
Programmable: MEMOBUS/Modbus (0x4D)
Monitor parameter U1-25
YASKAWA ELECTRIC SIEP YEACOM 01A V1000 Option EtherNet/IP Technical Manual