6.3.3.

Partitions

6.3.3.1. Partittion 1 / 2
In that tab you can assign the zones from 1 to 16 to the specific monitoring
partitions. If the zone is not assigned to any of the partitions (and it is not of 24h
type), all events received from that zone (disruption/return) will be ignored.
6.3.3.2. Entry / Exit
The parameter allows switching off the indication of time for entry/ exit displayed by
KP16 keypad.
6.3.3.3. Time for exit
It is time for leaving the partition. Assigned zones will be active (monitored) after the
expiration of pre-defined time, counting from the time the arming zone was
disrupted.
6.3.3.4. Alarm time
The parameter defines the time the alarm will be indicated by KP16 keypad.
6.3.3.5. Partition name
The parameter allows you to give any name for the partition.
CPX220NWB ALARM CONTROL UNIT – INSTALLER MANUAL
73 / 123