time for entry. If the system is armed, the line activation initiates counting the
time for entry to a particular partition. The system should be disarmed before the
expiration of programmed time in order not to trigger the alarm.
 24h burglary – that line causes immediate alarm irrespectively of whether the
system is armed or not.
 Arming/disarming – the line can be used for arming or disarming the system.
In case the line is activated with the system disarmed, the partition assigned to
the line is armed. In case the line is activated with the system armed, the partition
assigned to the line is disarmed.
 24h tamper – the line can be used for connecting tamper/sabotage circuits. In
case of trigger when partition is disarmed, it generates "violation of the zone"
event without the alarm. In case of trigger when partition is armed, it generates
"violation of the zone" event and raises the alarm.
 Interior delay – the line can be used when keypad is not in the first partition
which could be triggered during access to the keypad. In case of the interior delay
partition is triggered, system checks if time for enter is counting. If yes, the line is
treated as delay line. If not, the lien is treated as instant line.
 24h burglary silent – sends a report to the central station but provides no
keypad display or sounding.
 24h fire – works like 24h burglary.
 Perimeter – This zone will be armed immidiately after arm command. Violation of
this zone will raise the alarm, even during the exit time countdown.
 Perimeter exit – Violating this zones during exit time countdown will arm the
system in the away mode. If this is not violated during exit time countdown,
partition will be armed in the stay mode. If the system is armed, this zone
behaves like the delayed zone.
CPX220NWB ALARM CONTROL UNIT – INSTALLER MANUAL
67 / 123