After entering the function PROG LED is blinking, the other LEDs are off. Pressing
deletes all remote controllers, generating 3 beeps and exit the function. If you press
key will exit the function and remote controllers will not be erased.

4.3.11. Emergency buttons

To configure emergency buttons, use the following pattern:
where:
XX
– emergency button:
01 – fire
02 – help
03 – panic
00 – all buttons above
Y
– enable/disable emergency button:
0 – disable emergency button
1 – enable emergency button:
o 1 – output 1
o 2 – output 2
o 3 – output 3
After service command confirmation, there will be digits displayed which represent outputs
activated by emergency button. Use digits 1-3 to change this setting.
Functions which configure all three buttons, will not change the outputs setting.
Example:
a) enabling all emergency buttons:
b) enabling "panic" (burglary) function (
output 3 state:
CPX220NWB ALARM CONTROL UNIT – INSTALLER MANUAL
<XX> <Y>
held) and changing output 2 and
key