9.1.2.2. KILL
Format:
Limitations:
Description
9.1.2.3. RESET
Format:
Limitations:
Description
9.1.2.4. DESC
Format:
Limitations:
Description
9.1.2.5. GETCFG
Format:
Limitations:
Description
CPX220NWB ALARM CONTROL UNIT – INSTALLER MANUAL
KILL
Can be executed by ATS only
Restarts the GSM modem in the device. This results in breaking a GPRS
session and deregistration from the GSM network and re-registration to
GSM and GPRS network when you restart the modem.
RESET
Can be executed by ATS only
Restarts the whole device. This results in breaking a GPRS session and
deregistration from the GSM network and re-registering to GSM and GPRS
network when you restart the device and modem.
DESC
Can be executed by ATS only
Returns a string with a description of the device containing firmware
version and serial number
GETCFG
Returns max. 160 characters, can be executed by ATS only
Gets the current, basic configuration of the device. The parameters are
returned in the following order:
SERVER:PORT, _APN_UN_PW,_DNS0
Where:
_ Space character (asci 0x20)
SERVER – OSM server address
PORT – OSM server port
APN – APN name by means of which the GPRS session is compiled
UN – APN user name
PW –APN password
DNS0 –DNS server address