EBS CPX220NWB Installation And Programming Manual page 120

Alarm control unit
Table of Contents

Advertisement

9.1.4.6. CPZONESUNLOCK
Format:
Limitations:
Description
CPX220NWB ALARM CONTROL UNIT – INSTALLER MANUAL
CPZONESUNLOCK=zones[,password]
You must know the administrator or user password. Can be executed
by ATS, administrator or user. If the command comes from ATS and
was not authorized with a code, enter the password.
Removes permanent and temporary blockade from the given zones.
It generates the events INPUTx_UNLOCK.
Zones is a bit-vector indicating the zones, which one wants to
unblock. Bit 1 (counting from 0) means the zone 1. Sending the
commands with the argument of zones equal to 0, has no sense,
since it does not change anything. Password is the system
dministrator or user password.
The command returns:
CPZONESUNLOCK:EOK,zones
If the command is executed
CPZONESUNLOCK:ENOT_ALLOWED
If the command was sent via open SMS
CPZONESUNLOCK:EFORMAT
If the format of the sent command is incorrect
CPZONESUNLOCK:EPERMISIONS
If the user has not authorization to the proper partition
CPZONESUNLOCK:ENOT_EXISTS
If the user with the specified password does not exist