Y – number of parameter related to a given remote control:
 0 – complex function, the initiation of which configures the parameters listed below
as set of parameters:
 1 – Delete a remote control. After selecting this option, you can confirm deleting by
pressing
 2 – Add a remote control. After selecting this option, any key on the remote control
has to be pressed. Once the transmission with the remote control is established serial
number will be displayed on the keypad (hexadecimal value). If accepted, the remote
control will be saved.
3 – type of the remote control (read only)
o 0 – no remote control
o 1 – P300 remote control
o 2 – RC-10 remote control
4 – The use to which the remote control is assigned
5, 6, 7, 8 – buttons functions:
o 0 – no fuction
o 1 – arm
o 2 – disarm
o 3 – alarm
o 4 – silent alarm
o 5 – enable output 1
o 6 – enable output 2
o 7 – enable output 3
o 8 – disable output 1
o 9 – disable output 2
o 10 – disable output 3
Note:
„Alarm" function is triggering an alarm with audible signal.
„Silent alarm" function is triggering an alarm without audible signal.
Alarms from remote control can be generated regardless of whether or not the partition is
armed. For normal and silent alarm can be sent a message to the monitoring station,
depending on the configuration of the control panel.
Example:
a) delete a remote control no. 1:
b) add a remote control no. 1:
4.3.10.2. Delete all remote controllers
To remove all remote controllers from the system, enter the following function: